SB-0758, As Passed House, June 12, 2018
SB-0758, As Passed Senate, April 12, 2018
SUBSTITUTE FOR
SENATE BILL NO. 758
A bill to amend 1972 PA 230, entitled
"Stille-DeRossett-Hale single state construction code act,"
by amending section 28a (MCL 125.1528a), as amended by 2017 PA 126.
THE PEOPLE OF THE STATE OF MICHIGAN ENACT:
Sec. 28a. (1) Notwithstanding any other provision of this act
or the code, a permit is not required under this act or the code
for the installation, maintenance, replacement, or servicing of any
electrical wiring, equipment, or devices related to or associated
with
a business monitoring system, or with a home monitoring
system, or with a low-voltage electric fence if performed by a
provider.
(2) As used in this section:
(a) "Business monitoring system" means a device or an assembly
of equipment and devices, less than 50 volts, that allows a
business to remotely monitor its business premises through audio,
video, or sensor detection systems. A business monitoring system
does not include a fire alarm system or a life safety system
designed to protect and evacuate building occupants in the event of
emergencies such as fire, smoke, or power outages.
(b) "Home monitoring system" means a device or an assembly of
equipment and devices that allows an individual to remotely monitor
his or her home through audio, video, or sensor detection systems
and that may allow the individual to remotely control the home's
environment, including, but not limited to, temperature, humidity,
lighting, doors, or locks.
(c) "Low-voltage electric fence" means an alarm system that
consists of a fence structure and an energizer that produces an
electric charge on contact with the fence structure and meets all
of the following:
(i) The low-voltage electric fence is installed in a location
that is zoned for nonresidential use.
(ii) The energizer is powered by a commercial storage battery
that does not exceed 12 volts.
(iii) The electric charge produced by the low-voltage electric
fence upon contact does not exceed energizer characteristics set
forth in paragraph 22.108 and depicted in figure 102 of
international electrotechnical commission standard, IEC 60335-2-76,
current edition.
(iv) The low-voltage electric fence is identified using
warning signs attached to the fence at intervals of not more than
60 feet. Each sign shall include the international symbol for shock
and be in both English and Spanish.
(v) The low-voltage electric fence is designed so that access
to or within a fenced area is restricted because of secured
openings or where immediate access is necessary for life-saving or
firefighting purposes. A fire code official may require a key box
to be installed in an accessible location. The key box shall be of
an approved type listed in accordance with UL 1037, and shall
contain keys to gain access as required by the fire code official.
(vi) The low-voltage electric fence is completely enclosed by
a nonelectric fence or wall.
(d) (c)
"Provider" means any of
the following:
(i) A system provider that is registered under the security
alarm systems act, 2012 PA 580, MCL 338.2181 to 338.2187.
(ii) A security alarm system contractor licensed under the
private security business and security alarm act, 1968 PA 330, MCL
338.1051 to 338.1092.